CUSTOMIZABLE MEDICAL DESKTOP POWER ADAPTERS

Medical Desktop Power Supply with Customizable to Fast Regulatory Approval

Powering a new product design can invites additional complexity for designers bringing a new product to market. Designing for safety, emissions, and regulatory standards alone can stop a project from obtaining that critical regulatory approval, piling on additional testing and engineering costs.  In addition, the final product will dictate the power demand, so it makes no sense for new product to be designed with a power converter in mind. 

Let ETA-USA’s external, desktop style power supplies deliver the DC voltage you need in a pre-approved device and  save time and effort of designing the power conversion in your system. ETA-USA desktop adapters hold UL, TUV, and UKCA 60601-1 safety certifications and meet FCC conducted and radiated emissions standards.  

Most important, ETA-USA custom DC connector program allows you to pick the DC interface of your choice. Choose from our pre-approved connector list or contact a technical representative with connector you want to use and the power requirement you need. Our staff are trained to ensure the connector will meet regulatory safety compliance and can recommend substitutes if needed. Best of all, ETA-USA has a low minimum order quantity for custom connector options (30 pcs) and customers can procure 1-2 evaluation units to test before they commit to a final design.  

See some of our  popular desktop Medical adapter models below, and contact an ETA-USA representative . All models are RoHS/REACH and DOE VI compliant.

All ETA-USA products are TAA compliant. 

Standard models can be purchased from an Authorized ETA-USA Distributor. Customized options can be ordered from an ETA-USA sales representative.

65W Medical Desktop Adapter- MDL65 Series

MDL65-SX-W6

  • Universal Input: AC 100~240V 50/60 Hz
  • IEC320-C14 AC inlet  (3 prong)
  • No load power consumption <150mW
  • 2 MOPP; Suitable for BF application and Isolation Voltage 5,656 VDC
  • Available Voltages: 5, 12, 15, 19, 24, 28, 36, 48
  • Short circuit, OVP, OCP protection
  • Operating Temp: -20°C~60°C
  • UL/TUV/EN 60601-1 Safety, FCC 15 Class B
  • Customized cable and DC connector available

140W Medical Desktop Adapter- MTE140 Series

MTE140-SX-WL6

  • Universal Input: AC 100~240V 50/60 Hz
  • IEC320-C14 AC inlet  (3 prong)
  • No load power consumption <150mW
  • 2 MOPP; Suitable for BF application
  • Available Voltages:  12, 15, 19, 24, 28, 36  48, 54
  • Short circuit, OVP, OCP protection
  • Operating Temp: -20°C~60°C
  • UL/TUV/EN 60601-1 Safety, FCC 15 Class B
  • Customized cable and DC connector available

175W Medical Desktop Adapter- MTE175 Series

MTE175-SX-F-W6

  • Universal Input: AC 100~240V 50/60 Hz
  • IEC320-C14 AC inlet  (3 prong); 
  • Leakage less than 100uA
  • 2 MOPP; Suitable for BF application
  • Available Voltages: 12, 15, 19, 24, 28, 36  48, 54
  • Short circuit, OVP, OCP protection
  • Operating Temp: -20°C~60°C
  • UL/TUV/EN 62362-1 Safety, FCC 15 Class B
  • Customized cable and DC connector available & Optional C6 Inlet available 

300W ITE & Medical Desktop Adapter- DTMF300 Series

DTMF300-SX-F-W6

  • Universal Input: AC 100~240V 50/60 Hz
  • IEC320-C14 AC inlet  (3 prong) or IEC320-C18 (2 prong)
  • I/O switch optional, meets IP42 with I/O switch removed
  • 2x MOPP and BF applications
  • No load power consumption <0.5W
  • Available Voltages: 12, 15, 19, 24, 28, 48, 54
  • Short circuit, OVP, OCP protection
  • Operating Temp: -30°C~60°C
  • UL/TUV/EN 62362-1 (ITE) & 60601-1 (Medical) Safety, FCC 15 Class B
  • Customized cable and DC connector available

400W ITE & Medical Desktop Adapter- DTMF400 Series

DTMF400-SX-F-W6

  • Universal Input: AC 100~240V 50/60 Hz
  • IEC320-C14 AC inlet  (3 prong)
  • Meets IP42
  • 2x MOPP and BF applications
  • No load power consumption <0.5W
  • Available Voltages: 12, 15, 19, 24, 28, 48, 54
  • Short circuit, OVP, OCP protection
  • Operating Temp: -30°C~60°C
  • UL/TUV/EN 62362-1 (ITE) & 60601-1 (Medical) Safety, FCC 15 Class B
  • Customized cable and DC connector available

Government and Federal Agency  Customers

ETA-USA is ready to work with the US government. See our capabilities page for more information. Government P-cards accepted. 

CUSTOMIZABLE ITE EXTERNAL DESKTOP POWER ADAPTERS

ITE Desktop Power Supply with Customizable to Fast Regulatory Approval

Powering a new product design can invites additional complexity for designers bringing a new product to market. Designing for safety, emissions, and regulatory standards alone can stop a project from obtaining that critical regulatory approval, piling on additional testing and engineering costs.  In addition, the final product will dictate the power demand, so it makes no sense for new product to be designed with a power converter in mind. 

Let ETA-USA’s external, desktop style power supplies deliver the DC voltage you need in a pre-approved device and  save time and effort of designing the power conversion in your system. ETA-USA desktop adapters hold UL, TUV, and UKCA 62368-1 safety certifications and meet FCC conducted and radiated emissions standards.  

Most important, ETA-USA custom DC connector program allows you to pick the DC interface of your choice. Choose from our pre-approved connector list or contact a technical representative with connector you want to use and the power requirement you need. Our staff are trained to ensure the connector will meet regulatory safety compliance and can recommend substitutes if needed. Best of all, ETA-USA has a low minimum order quantity for custom connector options (30 pcs) and customers can procure 1-2 evaluation units to test before they commit to a final design.  

See some of our  popular desktop ITE adapter models below, and contact an ETA-USA representative . All models are RoHS/REACH and DOE VI compliant.

All ETA-USA products are TAA compliant. 

Standard models can be purchased from an Authorized ETA-USA Distributor. Customized options can be ordered from an ETA-USA sales representative.

65W ITE Desktop Adapter- DTL65 Series

DTL65-SX-W6

  • Universal Input: AC 100~240V 50/60 Hz
  • IEC320-C14 AC inlet  (3 prong)
  • No load power consumption <210mW
  • Available Voltages: 5, 12, 15, 19, 24, 36, 48
  • Short circuit, OVP, OCP protection
  • Operating Temp: 0°C~60°C
  • UL/TUV/EN 62362-1 Safety, FCC 15 Class B
  • Customized cable and DC connector available

DTL65-SX-WL6

  • Universal Input: AC 100~240V 50/60 Hz
  •  3-pole IEC320-C6 and 2-pole C8 AC inlet available
  • No load power consumption <150mW
  • Meets LPS (Limited Power Source) Requirements
  • Available Voltages:  12, 15, 19, 24, 28,  48
  • Short circuit, OVP, OCP protection
  • Operating Temp: -20°C~70°C
  • UL/TUV/EN 62362-1 Safety, FCC 15 Class B
  • Customized cable and DC connector available

120W ITE Desktop Adapter- DTD120 Series

DTD120-SX-F-W6

  • Universal Input: AC 100~240V 50/60 Hz
  • IEC320-C14 AC inlet  (3 prong)
  • No load power consumption <150mW
  • Available Voltages: 12, 15, 19, 24, 28, 48
  • Short circuit, OVP, OCP protection
  • Operating Temp: -20°C~70°C
  • UL/TUV/EN 62362-1 Safety, FCC 15 Class B
  • Customized cable and DC connector available

300W ITE & Medical Desktop Adapter- DTMF300 Series

DTMF300-SX-F-W6

  • Universal Input: AC 100~240V 50/60 Hz
  • IEC320-C14 AC inlet  (3 prong) or IEC320-C18 (2 prong)
  • I/O switch optional, meets IP42 with I/O switch removed
  • 2x MOPP and BF applications
  • No load power consumption <0.5W
  • Available Voltages: 12, 15, 19, 24, 28, 48, 54
  • Short circuit, OVP, OCP protection
  • Operating Temp: -30°C~60°C
  • UL/TUV/EN 62362-1 (ITE) & 60601-1 (Medical) Safety, FCC 15 Class B
  • Customized cable and DC connector available

400W ITE & Medical Desktop Adapter- DTMF400 Series

DTMF400-SX-F-W6

  • Universal Input: AC 100~240V 50/60 Hz
  • IEC320-C14 AC inlet  (3 prong)
  • Meets IP42
  • 2x MOPP and BF applications
  • No load power consumption <0.5W
  • Available Voltages: 12, 15, 19, 24, 28, 48, 54
  • Short circuit, OVP, OCP protection
  • Operating Temp: -30°C~60°C
  • UL/TUV/EN 62362-1 (ITE) & 60601-1 (Medical) Safety, FCC 15 Class B
  • Customized cable and DC connector available

Government and Federal Agency  Customers

ETA-USA is ready to work with the US government. See our capabilities page for more information. Government P-cards accepted. 

MULTIPLE OUTPUT DESKTOP POWER SUPPLY-DTE180 SERIES

ETA-USA offers several model lines of dual and triple output AC/DC and DC/DC converters in chassis mount, PCB mount, and external desktop adapter for ITE applications. All models are and TAA compliant and available to purchase from an ETA-USA authorized distributor.

The DTE series is an external desktop style AC/DC multiple output power supply that provides 180W of rated DC power. Additional multiple output series can be found below. 

· Chassis mount AC/DC  WR series · PCB mount AC/DC  DAC series · PCB mount DC/DC multiple output O series · Desktop adapter multiple output DTE180 series ·

AC/DC Desktop Multiple Output Power Supply-DTE180 

Input: AC 90-264V 50/60Hz

              Current:  3 Arms max

              Inrush: 25A @ 115V, 50A @ 230V Max at Cold start

              Power factor: > 0.95 @115VAC; > 0.90 @230VAC @full load

Inlet: IEC320-C14

Dual Output- 0512: +5V @ 14A, +12V @ 15A

Dual Output- 1212: +12V@ 15A, -12V @ 1A

Triple Output- 03X: +5V @ 14A, +12V @ 15A, -12V @ 1A

Efficiency: >86% Typical

Operating Temp:  -20°C~60°C

Compliance : DOE VI, RoHs3, REACH, UL/EN/TUV/UKCA/IEC 62368-1, FCC Class B


DTE180 Series Customization

As with all ETA-USA desktop adapters, we offer customer specified DC connector and cable assemblies with a low minimum order. Our semi-custom page showcases DC connector options with no impact on unit costs. Customers are welcomed to specify their own connector also, contact an ETA-USA  representative for more information or to request an evaluation unit.


Government and Federal Agency  Customers

ETA-USA is ready to work with the US government. See our capabilities page for more information. Government P-cards accepted. 

MIL-STD-1399 Explained: Power Interface Standards for Naval Systems

MIL-STD-1399 Explained: Power Interface Standards for Naval Systems

When designing electronic equipment for naval ships, it’s not enough to just survive harsh sea conditions. Your system also needs to integrate seamlessly with the ship’s power infrastructure—and that’s where MIL-STD-1399 comes in.

This critical military standard ensures that all electronic equipment on board a ship can communicate, function, and interoperate reliably with shipboard power and signal interfaces.

In this post, we’ll explain what MIL-STD-1399 is, why it’s important, and what engineers need to know when designing equipment for naval vessels.

If you are looking for Mil-Std 1399 compliant AC/DC power supply,  ETA-USA’s Military Grade Power Supplies all comply with Type I single phase 60Hz  systems.

For information on the most up to date requirements of 1399, see our blog page on MIL-STD 1399 Sec 300 Part 1 


 What Is MIL-STD-1399?

MIL-STD-1399 is a United States military standard that defines interface requirements for shipboard systems, particularly focusing on electrical power interfaces between the ship’s power distribution system and installed equipment.

It provides common interface definitions to ensure compatibility between:

  • Ship power supplies (AC/DC, frequency, voltage, etc.)

  • Electronic and electromechanical equipment installed on board

The standard is used widely in U.S. Navy and allied naval programs.


 What Does MIL-STD-1399 Cover?

MIL-STD-1399 is broken into several sections, each addressing a specific type of interface or system behavior. These sections are often treated as standalone documents depending on the application.

 Key Sections Include:

Section Title What It Covers
300A Electric Power, AC 440V/60Hz and 115V/60Hz shipboard AC power
300B Electric Power, DC DC power interfaces (commonly 24V or 28V)
070 Noise Limits, Interface and Control Limits on conducted/radiated noise and transients
480 Synchro Systems Electrical interface for synchro transmitters
470 Shipboard Grounding & Bonding Safety and EMI mitigation grounding standards
302 Power Conditioning Requirements For sensitive or mission-critical electronics

The most widely used section is MIL-STD-1399 Section 300 (AC and DC power), which standardizes voltage levels, frequency tolerances, power factor expectations, harmonic content, and electrical noise limits for shipboard power systems.


 MIL-STD-1399 Section 300A (AC Power) – Key Highlights

This section defines how shipboard equipment should behave on 60 Hz AC power, including:

  • Voltage ranges:

    • 440V 3-phase

    • 115V single-phase or line-to-neutral

  • Frequency:

    • Nominal 60 Hz, with allowable variations

  • Power factor:

    • Minimum 0.8 lagging

  • Voltage imbalance:

    • Max 3% phase-to-phase variation

  • Harmonic distortion:

    • Limits on total harmonic distortion (THD)

  • Transient tolerance:

    • Ride-through or reset behavior during surges and sags

Why it matters: If your system can’t tolerate the ship’s power quality, it could shut down, overheat, or interfere with other equipment—potentially jeopardizing mission readiness.

ETA-USA’s CH-M500CH-M1000 , and CH-M2000 series meets 115Vac 60Hz power profiles and used mil-approved D38999 connectors as standard.


MIL-STD-1399 Section 300B (DC Power) – Key Highlights

Section 300B covers DC-powered systems, typically using:

  • 24 VDC

  • 28 VDC

It specifies:

  • Voltage regulation tolerances

  • Ripple voltage limits

  • Load step response

  • Noise immunity and conducted emissions

This section is especially relevant for:

  • Fire control systems

  • Lighting and emergency gear

  • Communication equipment


 Who Needs to Comply?

MIL-STD-1399 applies to:

  • OEMs building systems for naval platforms

  • System integrators developing shipboard electronics

  • Defense contractors working with the U.S. Navy or allies

Any electronic system that plugs into ship power must be tested for compatibility, stability, and survivability under MIL-STD-1399 specifications.


 How Compliance Is Verified

While MIL-STD-1399 itself doesn’t prescribe test procedures, compliance is typically verified through:

  • Interface Control Documents (ICDs)

  • Power conditioning analysis

  • Bench testing using MIL-STD power simulators

  • Lab or on-board trials under nominal and off-nominal conditions

EMC compliance testing is often done in parallel using MIL-STD-461.


 Design Considerations for MIL-STD-1399

If you’re developing shipboard equipment, here’s what you should do early:

  •  Design for wide AC voltage and frequency tolerance

  •  Include EMI filters to reduce conducted emissions

  •  Provide hold-up time for power sags

  •  Confirm grounding schemes meet ship standards

  •  Test with power simulation equipment mimicking naval power profiles

 Pro tip: MIL-STD-1399 is not just a design goal—it’s a system integration requirement. Even if your product is COTS (commercial off the shelf), it must be qualified for shipboard use.


MIL-STD-1399 ensures that shipboard systems don’t just function—they integrate. It prevents power issues, communication errors, and costly retrofits by defining clear electrical expectations upfront.

For naval electronics, it’s not enough to be rugged and high-tech. You also need to be electrically compatible with the rest of the ship. MIL-STD-1399 bridges that gap between smart technology and real-world integration. Here are some of ETA-USA’s products designed to meet MIL-STD-1399 :

CH-M500 Series

CH-M1000 Series

CH-M2000 Series

Are these what you’re looking for? ETA-USA can also design power supplies to meet your requirements. Please do not hesitate to contact us.

Customizing Your Power Solutions with ETA-USA

Endless Custom Power Supply Options

Thirty years of industry experience , ETA-USA has seen a plethora of unique requirements that is has engineered and can build upon to provide its customers solutions as specialized as their applications.

All of of products are TAA compliant. Rackmount, Military, Avionics, and IP65+ Rated products are made in the USA. CAD and STEP models available upon request.

Contact an ETA-USA Representative for Details

Customized AC/DC External Adapters, TAA Compliant.

External Adapters
Customizable AC/DC External Adapters

ETA-USA’s ITE and medical grade external power adapters can be customized to power your application requirements with low minimum order quantities and 1-2 piece evaluation units available to purchase.

  • 25W~400W ITE and Medical Grade Products
  • Single and Multiple Outputs
  • Customizable AC Inlets (select Models) DC out connector and Cables.
  • DOE VI and DOE VI Compliance
  • TAA Compliant
  • IP42
  • Customer Name and Part Number Can Be Added at no Additional Charge
  • UL, UK, CE, & TUV Safety Certified
  • US, UK, EU, & JP AC Cords Can be Ordered & Packaged with Product

 

Rackmount AC/DC & DC/DC Power Systems Made in the USA

AC/DC Custom Rackmount Power System

ETA-USA designed and built its first Rackmount for Alstom MUX Train Control system in 1998, which have been in use and operating for over 25 years without requiring service. ETA-USA can quickly deliver a robust and reliable rackmount power systems in as little as 8 weeks after order.

  • 19 Inch Rackmount Units at 1U, 2U, 3U, and 4U sizes
  • Up to 8 Separate & Isolated Outputs or 4 Outputs with Redundancy
  • LED Display with Voltage & Current Reading
  • Alarm Signals & Power Good Indicator
  • I2C Reporting Options Available
  • Industrial & Military Grade Options Available
  • DC/DC Models Available

Military & Defense

Mil-Grade AC/DC & DC/DC

ETA-USA is ITAR registered and all of its Mil-grade and Defense compliant power supplies are designed and built in the USA. ETA-USA maintains an NIST SP800 compliant

  • Conduction Cooled Single Output AC/DC Power Supplies form 500~2,000W, 50/60/400Hz Input Frequency
  • Convection Cooled Single and Multiple Output AC/DC Power Systems up to 6,000W
  • Single and 3 Phase Options
  • Convection and Conduction Cooled DC/DC Models, Meets Mil-Std 1279
  • Mil-Std 461. 810, & 1399 compliant. Mil-Std 910 enclosure Designs Available.
  • User Selectable D38999 or 5015 Connectors available.
  • Multiple, Isolated Output Voltages Available.
  • Anodized, Chromate, or Powder Coat finishes
  • Low MOQ
  • High Altitude Models Coming Soon

Semi-Custom Outdoor and Ingress Protection

IP65 for Explosive Environments

ETA-USA can package its designs into an IP65+ Rated enclosure to be used in rugged and outdoor environments.

  • Selection of Proven designs for AC/DC & DC/DC requirements form 300~1,400W
  • Heatsink Design Capability for High Wattage, Environmentally Sealed
  • IECeX for Explosive Environment Model Line Available
  • View Semi-Custom Page for Baseline Models

Custom Design Capabilities

  • Rapid Design to Prototype Cycle
  • Non-Standard Input & Output Voltages, Isolation Voltages
  • Low and High Volume manufacturing
  • CAD models available
  • EMI & Temperature Testing
  • Engineering experience to meet Commercial, Industrial,  Military, and Aviation standards
  • ISO 9001 2015 Certified, AS9100 Compliant
  • Engineering and Technical Support to Obtain 3rd Party Certification